PacAtlantic, Inc. - North American distributor of sound and visual signal equipment manufactured by Zöllner GmbH.

Marine EquipmentElectric Horns & Whistles

Zet-Horn 90 AC
Zet-Horn 90 AC

SHIP CLASS I - SHIP LENGTH 200 METRES OR MORE

Class requirements:

  • Limits of fundamental frequencies: 70-200 Hz
  • Intensity in 1/3rd-octave band level at 1 m distance, referred to 2x10-5 N/m²: 143 dB

Specifications:

  • BSH type approval DHI 49/02 P/01/78
  • Operating on AC 3phase
  • Intensity: 143 dB
  • Fundamental frequency: 90 Hz
  • Technical Data PDF Document

Zet-Horn 110 AC
Zet-Horn 110 AC

SHIP CLASS I - SHIP LENGTH 200 METRES OR MORE

Class requirements:

  • Limits of fundamental frequencies: 70-200 Hz
  • Intensity in 1/3rd-octave band level at 1 m distance, referred to 2x10-5 N/m²: 143 dB

Specifications:

  • BSH type approval DHI 49/02 P/02/95
  • Operating on AC 3phase
  • Intensity: 143 dB
  • Fundamental frequency: 110 Hz
  • Technical Data PDF Document

Zet-Horn 70 AC
Zet-Horn 70 AC

SHIP CLASS I - SHIP LENGTH 200 METRES OR MORE

Class requirements:

  • Limits of fundamental frequencies: 70-200 Hz
  • Intensity in 1/3rd-octave band level at 1 m distance, referred to 2x10-5 N/m²: 143 dB

Specifications:

  • Waterproof Electricals
  • BSH type approval Nr. 6375/003/00
  • Operating on AC 3phase
  • Intensity: 143 dB
  • Fundamental frequency: 70 Hz
  • Technical Data PDF Document

Zet-Horn 131 AC
Zet-Horn 131 AC

SHIP CLASS II - SHIP LENGTH 75 BUT LESS THAN 200 METRES

Class requirements:

  • Limits of fundamental frequencies: 130-350 Hz
  • Intensity in 1/3rd-octave band level at 1 m distance, referred to 2x10-5 N/m²: 138 dB

Specifications:

  • BSH type approval DHI 49/01 P/01/78
  • Operating on AC 3phase
  • Intensity: 138 dB
  • Fundamental frequency: 130 Hz
  • Technical Data PDF Document

Zet-Horn Control (For all types of Zet-Horns)
Zet-Horn Control (For all types of Zet-Horns)

Specifications:

  • Main voltage AC 3phase, control voltage AC 1phase
  • With anti-condensation heating, casing and bi-metal relay

ZETFON 400/310
ZETFON 400/310

SHIP CLASS III - SHIP LENGTH 20 BUT LESS THAN 75 METRES

Class requirements:

  • Limits of fundamental frequencies: 250-700 Hz
  • Intensity in 1/3rd-octave band level at 1 m distance, referred to 2x10-5 N/m²: 130 dB

Specifications:


ZETFON Control and Amplifier AC (For ZETFON 400/310 AC)
ZETFON Control and Amplifier AC (For ZETFON 400/310 AC)

Specifications:

  • Electronic sound generator and amplifier
  • Main voltage AC 1phase emergency voltage 24 V DC

ZETFON Control and Amplifier DC (For ZETFON 400/310 DC)
ZETFON Control and Amplifier DC (For ZETFON 400/310 DC)

Specifications:

  • Operating on 24 V DC
  • Electronic sound generator and amplifier

« Return to Marine Equipment

PDF Document Adobe Portable Document Format (PDF) documents are used within this website. Adobe Acrobat® is required to view these PDF files. If you do not have Adobe Acrobat® installed, please download and install the free Adobe Acrobat Reader®.

Website designed and maintained by PROWEBWORKS.NET