Zöllner signal systems are precision engineered and manufactured in Kiel, Germany, on the southwestern shore of the Baltic Sea. Zöllner is among the most successful global producers of acoustic signal equipment due to their high quality, reliability, and low life cycle costs. Zöllner is also one of the few companies that offers complete signal systems, including horns, bells, gongs, sound reception devices, inclinometers, and signal control. Zöllner products are commonly found across a broad range of applications, including Marine, Rail, Arena/Stadium, and Industrial.
Showing all 29 results
-
Makrofon M75F/260
- Frequency: 260 Hz
- Intensity @ 1m: 138 dB(A)
- Ship Class: II, III
- Power Source: Compressed Air
-
Makrofon M75F/370
- Frequency: 370 Hz
- Intensity @ 1m: 132 dB(A)
- Ship Class: III, IV
- Power Source: Compressed Air
-
Makrofon M75F/370 HVEF
- Frequency: 370 Hz
- Intensity @ 1m: 132 dB(A)
- Ship Class: III, IV
- Power Source: Compressed Air
-
Zetfon 300/310
- Frequency: 310 Hz
- Intensity @ 1m: 131 dB(A)
- Ship Class: III
- Power Source: Electric
-
Zetfon 300/310 Control Box
- System Voltage: 24 V DC
- For use with Zetfon 300/310
-
Zetfon 400/310
- Frequency: 310 Hz
- Intensity @ 1m: 131 dB(A)
- Ship Class: III
- Power Source: Electric
-
Zetfon Control Box AC ZP-4
- System Voltage: AC 1 phase (115V/230V); Emergency voltage 24V DC
- For use with Zetfon 400/310
-
Zetfon Control Box DC ZP-5
- System Voltage: 24 V DC
- For use with Zetfon 400/310
-
1+ Automaton Controller
- System Voltage: AC 3 phase
- For use with 350EL Bell and 500EL Gong
-
Zetfon 50/650K
- Frequency: 650 Hz
- Intensity @ 1m: >120 dB(A)
- Ship Class: IV
- Power Source: Electric
-
Zetfon 120/330K
- Frequency: 330 Hz
- Intensity @ 1m: >120 dB(A)
- Ship Class: IV
- Power Source: Electric
-
Fonomat 1×70
- Frequency: 310 Hz
- Intensity @ 1m: 124 dB(A)
- Ship Class: IV
- Power Source: Electric
-
Fonomat 4×70
- Frequency: 310 Hz
- Intensity @ 1m: 134 dB(A)
- Ship Class: II, III
- Power Source: Electric
-
Manual Bell 200M
- Ship Class: IV
- System Voltage: Manual
- Intensity @ 1M: >110 db(A)
- Materials: Brass; corrosion and seawater resistant
- Audibility Range: .5 NM
-
Manual Bell 300M
- Ship Class: I, II, III
- System Voltage: Manual
- Intensity @ 1M: >110 db(A)
- Materials: Brass; corrosion and seawater resistant
- Audibility Range: 2 NM
-
Manual Gong 500M
- Ship Class: I, II, III
- System Voltage: Manual
- Intensity @ 1M: >110 db(A)
- Materials: Brass; corrosion and seawater resistant
- Audibility Range: 2 NM
-
Electro-Mechanical Bell 350EL
- Ship Class: I, II, III
- System Voltage: Same as Signal Automaton
- Intensity @ 1M: >110 db(A)
- Materials: Brass; corrosion and seawater resistant
- Audibility Range: 2 NM
-
Electro-Mechanical Gong 500EL
- Ship Class: I, II, III
- System Voltage: Same as Signal Automaton
- Intensity @ 1M: >110 db(A)
- Materials: Brass; corrosion and seawater resistant
- Audibility Range: 2 NM
-
Signal Automaton 1+
- System Voltage: AC 1 phase (115V/230V) or 24 V DC
- For electro-mechanical bell and gong
-
Electronic Bell ZB110
- Ship Class: I, II, III
- System Voltage: Same as Signal Automaton
- Intensity @ 1M: >110 dB(A) db(A)
- Materials: Corrosion and seawater resistant
- Audibility Range: 2 NM
-
Electronic Gong ZG110
- Ship Class: I, II, III
- System Voltage: Same as Signal Automaton
- Intensity @ 1M: >110 dB(A) db(A)
- Materials: Corrosion and seawater resistant
- Audibility Range: 2 NM
-
Signal Automaton 6+S
- System Voltage: AC 1 phase(115V/230V) and/or 24 V DC
- For all Zöllner horns with electric signal release
- Six different signals
-
Signal Automaton 10+SGA
- System Voltage: AC 1 phase (115V/230V) or 24 V DC
- For all Zöllner horns with electric signal release
- Ten different signals
-
General Alarm Automaton GAV 4.3
- System Voltage: AC 1 phase (115V/230V) or 24 V DC
- General alarm, abandon ship
-
Signal Keys/Pushbuttons
- Push buttons to sound horn, signal lamp, general alarm, abandon ship, all clear, etc.
-
Maneuver Signal Lamp TS1a LED
- System Voltage: AC 1 phase (115V/230V) or 24 V DC
-
Maneuver Signal Lamp TS1a
- System Voltage: AC 1 phase (115V/230V) or 24 V DC
-
Sound Signal Direction Detector SRD 414/4
- System Voltage: 24 V DC 30 % / - 10 %
- Allows officer on watch to hear outside sound signals inside a fully enclosed bridge
-
ZEI-1 Electronic Inclinometer
- System Voltage: 24 V DC
- Heal & pitch measuring instrument